TAKMOSPRODUCTION ERP
Excel templates FREE Try the demo
Home › Guides › How to write an 8D report: D0–D8 step by step, with an example
Quality

How to write an 8D report: D0–D8 step by step, with an example

Hüseyin Şamlı · 2026-11-08 · 7 min read

An 8D report is the standard way to work through a quality problem in eight disciplines and close it for good. When a customer complaint arrives, it is usually the first document the customer asks for. A good 8D tells the customer "we have seen the problem, you are protected, we found the cause and it will not happen again" and backs this up with evidence. In this guide I walk through every step from D0 to D8 using one example: what to write in each step, how to use the 5 Whys and what auditors look at. A free Excel template is at the end.

What is 8D and where does it come from?

8D (Eight Disciplines) became widespread through Ford's "Team Oriented Problem Solving" (TOPS) manual, published in 1987. In the late 1990s Ford updated the method as "Global 8D" (G8D) and added a preparation step at the start, D0. Today almost every automotive customer asks for an 8D or a format very close to it.

IATF 16949 does not prescribe a specific form. Clause 10.2.3 requires a documented problem-solving process, and clause 10.2.4 requires the use of error-proofing methods. 8D is the most common way to meet both clauses.

When do you open an 8D?

Do not open an 8D for every defect. For a one-off issue with a known cause that has already been fixed, a short corrective action record is enough. Keep 8D for problems whose root cause is unknown, that reached the customer or that keep coming back.

The example problem

Throughout this guide I use a fictitious example: door panel clips produced on an injection moulding line break at the leg while being fitted on the customer's assembly line. 37 broken clips have been reported over two shifts.

D0–D8 step by step

D0 · Preparation and emergency response

You decide whether the problem needs an 8D. If the customer's line is at risk of stopping, you start the emergency response here: sending replacement parts or placing your own inspector at the customer's line, for example. In the example the customer's line is at risk and the root cause is unknown, so an 8D is opened.

D1 · Team

List the people who can actually solve the problem: quality, production, process, maintenance and a sponsor who approves decisions. Appoint a team leader. Write people's names, not department names such as "Quality". In the example, the root cause would not have been found without the maintenance technician who knows the dryer.

D2 · Problem description

Turn the problem into a measurable statement. Answering the 5W2H questions (what, where, when, who, how, how many) for both "is" and "is not" narrows down the search:

QuestionIsIs not
What?Clip leg breaks during fittingNo breaks on the body or other legs
When?Production of 4–5 May (2 lots)Earlier and later lots
How many?37 / 1,240 pcs (about 3%)0 in other lots

Problem statement: "About 3% of clips produced on 4–5 May break at the leg while being fitted on the customer line; no breaks in other lots." This statement already shows that the cause is a change limited to those two days.

D3 · Containment

The aim is to protect the customer immediately, even if the root cause is not yet known. List every place where suspect product could be: customer warehouse, shipments in transit, dispatch warehouse, work in progress and, if needed, the supplier. For each location, record the quantity checked and the quantity rejected. Mark the boxes that passed (clean-point marking) so that the customer knows from which shipment onwards they are safe.

Many customers expect containment to be in place within 24 hours and D3 to be reported quickly. Exact times vary by customer; check your customer-specific requirements (CSR).

D4 · Root cause analysis

This is where most 8Ds are weakest. Ask two separate questions:

First, collect possible causes in a fishbone (Ishikawa) diagram under the 6M headings: man, machine, method, material, measurement, environment. Confirm or rule out each possible cause with data. Then build the 5 Whys chain for the confirmed cause:

  1. Why did the clip break? The clip leg has low impact strength.
  2. Why is it low? The granulate was processed wet; the retained sample showed high moisture.
  3. Why was it wet? The dryer ran at a low temperature after maintenance on 4 May.
  4. Why was this not noticed? The dryer setting is not on the post-maintenance start-up checklist.
  5. Why is it missing? The checklist was written only for the main machine; auxiliary equipment was out of scope.

Build the escape chain separately: final inspection is visual and dimensional only, and the control plan has no mechanical test or moisture check for the clip. The most solid way to verify a root cause is to switch it on and off: if breakage returns when the dryer is deliberately set to a low temperature for a trial run, the root cause is confirmed.

D5 · Choose permanent corrective actions

Link at least one permanent action to each root cause (occurrence and escape). Give priority to error-proofing: actions that rely on someone remembering ("operator will take care", "training given") do not count as permanent. In the example the dryer set point will be read from the recipe and cannot be changed by hand, and the alarm will be linked to the set point. On the escape side, a moisture check at shift start and an hourly clip fitting test are added. IATF 16949 clause 10.2.4 also expects error-proofing devices to be covered in the PFMEA and tested regularly.

D6 · Implement and verify effectiveness

Prove that the action works, not just that you implemented it: zero defects over a defined period, confirmation from the customer line, a record showing the system refused a change to the set point. Once effectiveness is proven, remove the D3 containment and record the date; if both are forgotten, 100% inspection can go on for years.

D7 · Prevent recurrence and roll out

Update the system: PFMEA, control plan, work instructions, maintenance checklists. Then ask where else the same risk exists. In the example three more machines used the same type of dryer, and the action was applied to them too. If this step is not recorded, the same 8D returns a few months later under a different part number.

D8 · Closure and team recognition

Get the customer's approval, close the 8D, write the lessons learned and thank the team. Record the closure date; average closure time is one of the best indicators of your problem-solving process.

What response times do customers expect?

StepCommon expectation (general)
D3 containmentUsually within 24 hours
D4–D5 root cause and action planTypically from a few days to two weeks
D6–D8 verification and closureUsually within 30–60 days

These are general tendencies, not rules. Take the exact times from your customer-specific requirements and enter them as targets in your tracking sheet.

The 6 most common mistakes

What do auditors ask?

An auditor usually picks one 8D from the list and follows its trail:

  1. When was containment in place, and which stock locations did it cover?
  2. How was the root cause verified? Was the escape analysed?
  3. Are the actions error-proofing or just more inspection?
  4. Can the change be seen in the PFMEA and control plan?
  5. Was it rolled out to similar products and lines?
  6. How many 8Ds are open, and how many have exceeded their target time?

Free Excel template

The 8D and 5 Whys template has two parts. On the 8D Log sheet each 8D is one row; as you enter the D0–D8 dates, the status, last step, days open and D3/D5/D7/D8 delays are calculated automatically. The 8D Form sheet holds the content of a single 8D: team, is/is not table, containment by stock location, 6M fishbone, separate 5 Whys chains for occurrence and escape, actions, verification and D7 document updates. The Dashboard shows open and overdue 8Ds, average closure time and root cause categories. Target times are set on the Lists sheet; the sample data is fictitious.

When Excel is no longer enough

Once dozens of 8Ds are opened every year and actions are spread across departments, tracking them in Excel gets hard: an action passes its due date and nobody notices, and the PFMEA update sits in a separate file. In the Complaints and 8D section of the TAKMOS Quality Module, an 8D is opened from the complaint record, steps and actions are tracked in one place, and an 8D cannot be closed until the PFMEA and control plan are updated in D7.

8D and 5 Whys

An 8D log and a one-page 8D form for customer, supplier and internal nonconformities. D0–D8 dates are compared with target times; overdue 8Ds, average closure time and root cause categories on the dashboard.

Download (Excel · 148 KB)
Quality Module · Complaints and 8D

See how we do this in the program on the module page, and try it in the demo.

Explore →